|
|
|
|
LEADER |
06615nlm a2200745 4500 |
001 |
PPN268893624 |
003 |
http://www.sudoc.fr/268893624 |
005 |
20240917060000.0 |
029 |
|
|
|a FR
|b 2022ECDN0045
|
033 |
|
|
|a http://www.theses.fr/2022ECDN0045
|
035 |
|
|
|a (OCoLC)1374602224
|
035 |
|
|
|a STAR194175
|
100 |
|
|
|a 20230403d2022 k y0frey0103 ba
|
101 |
0 |
|
|a eng
|d fre
|d eng
|2 639-2
|
102 |
|
|
|a FR
|
105 |
|
|
|a ||||ma 00|yy
|
135 |
|
|
|a dr|||||||||||
|
181 |
|
|
|6 z01
|c txt
|2 rdacontent
|
181 |
|
1 |
|6 z01
|a i#
|b xxxe##
|
182 |
|
|
|6 z01
|c c
|2 rdamedia
|
182 |
|
1 |
|6 z01
|a b
|
183 |
|
|
|6 z01
|a ceb
|2 RDAfrCarrier
|
200 |
1 |
|
|a PWM control optimization of a two-level inverter
|e Application to electric and hybrid vehicles
|f Adrien Bourgeade
|g sous la direction de Malek Ghanes et de Maurice Fadel
|
214 |
|
1 |
|d 2022
|
230 |
|
|
|a Données textuelles
|
304 |
|
|
|a Titre provenant de l'écran-titre
|
314 |
|
|
|a Ecole(s) Doctorale(s) : École doctorale Mathématiques et sciences et technologies de l'information et de la communication (Rennes)
|
314 |
|
|
|a Partenaire(s) de recherche : Laboratoire des Sciences du Numérique de Nantes (Laboratoire)
|
314 |
|
|
|a Autre(s) contribution(s) : Mohamed Djemai (Président du jury) ; Malek Ghanes, Maurice Fadel, Mohamed Djemai, Stefano Di Gennaro, Pierre Riedinger, Xuefang Lin-Shi, Olivier Bethoux, Abdelkader Bouarfa (Membre(s) du jury) ; Stefano Di Gennaro, Pierre Riedinger (Rapporteur(s))
|
328 |
|
0 |
|b Thèse de doctorat
|c Génie Électrique
|e Ecole centrale de Nantes
|d 2022
|
330 |
|
|
|a Malgré les améliorations de topologies des convertisseurs DC/AC, l'onduleur à deux niveaux reste le "gold standard" dans l'industrie ceci pour de multiples raisons : simplicité, fiabilité, etc. Dans le cadre de cette thèse entre Centrale Nantes et Renault, de nouvelles commandes d'onduleur ont été développées afin d'améliorer les performances sans modifier la topologie du convertisseur. Pour cela, deux approches basées sur des commandes hors-ligne synchrones ont été proposées. Premièrement, celles qui relaxent la contrainte de symétrie angulaire entre phases, usuellement imposée au convertisseur. Deuxièmement, celles qui sont à porteuse triangulaire consistant à injecter une séquence homopolaire de fréquence triple dans la modulante. La conséquence de cette approche est une généralisation de l injection d'harmonique classique de rang trois. Un calcul aux limites a permis de montrer l'existence d'une méthodologie facilement implantable, qui prend la forme d'une injection d une dent de scie. Les deux approches revisitent les stratégies de commande par modulation de largeur d'impulsion (MLI) de la littérature grâce à des considérations simples à base de relaxation et d'extension de propriétés existantes. L'ensemble de ces stratégies améliorent significativement le taux de distorsion harmonique des tensions ou courants fournis par l'onduleur pour des fréquences de commutations synchrones faibles. Ces observations ont été réalisées en simulation et validées sur un banc expérimental de faible puissance.
|
330 |
|
|
|a Despite improvements in DC/AC converter topologies, the two-level inverter remains the "gold standard" in the industry for many reasons: simplicity, reliability, etc. In this thesis between Ecole Centrale and Renault, new inverter controls have been developed to improve the performance without modifying the converter topology. For this purpose, two approaches based on synchronous off-line controls have been proposed. Firstly, an angular symmetry relaxation between phases usually imposed on the converter. Secondly triangular carrier based strategies, meaning injecting a triple frequency homopolar sequence into the modulating signal. The consequence of this approach has given rise to a generalization of the classical third harmonic injection. A calculation extension has shown the existence of an easily implementable methodology, which takes the form of a sawtooth injection. Both approaches revisit the pulse width modulation (PWM) control strategies of the literature with simple considerations based on relaxation and extension of existing properties. The advantage of all these strategies is that they improve significantly the harmonic distortion rate of the voltages or currents supplied by the inverter for low synchronous switching frequencies. These observations have been done in simulation and validated on a low power experimental bench.
|
337 |
|
|
|a Configuration requise : un logiciel capable de lire un fichier au format : PDF
|
541 |
| |
|
|a Optimisation du contrôle par MLI d un onduleur à deux niveaux de tension
|e Application aux véhicules électriques et hybrides
|z fre
|
606 |
|
|
|3 PPN027580334
|a Onduleurs (électricité)
|2 rameau
|
606 |
|
|
|3 PPN027710025
|a Convertisseurs électriques
|2 rameau
|
606 |
|
|
|3 PPN032574428
|a Modulation d'impulsions en durée
|2 rameau
|
606 |
|
|
|3 PPN034842721
|a Automobiles
|x Commande automatique
|2 rameau
|
606 |
|
|
|3 PPN034516409
|a Véhicules électriques hybrides
|2 rameau
|
608 |
|
|
|3 PPN027253139
|a Thèses et écrits académiques
|2 rameau
|
610 |
0 |
|
|a MLI synchrone
|
610 |
0 |
|
|a Onduleur
|
610 |
0 |
|
|a Optimisation
|
610 |
0 |
|
|a Hors-ligne
|
610 |
0 |
|
|a Injection de séquence nulle
|
686 |
|
|
|a 620
|2 TEF
|
700 |
|
1 |
|3 PPN268606781
|a Bourgeade
|b Adrien
|f 1995-....
|4 070
|
701 |
|
1 |
|3 PPN103100563
|a Ghanes
|b Malek
|f 1976-....
|4 727
|4 555
|
701 |
|
1 |
|3 PPN033722781
|a Fadel
|b Maurice
|f 1958-....
|4 727
|4 555
|
701 |
|
1 |
|3 PPN156102315
|a Djemai
|b Mohamed
|f 1967-....
|4 956
|4 555
|
701 |
|
1 |
|3 PPN166705365
|a Di Gennaro
|b Stefano
|f 1963-
|4 958
|4 555
|
701 |
|
1 |
|3 PPN135446295
|a Riedinger
|b Pierre
|f 19..-....
|4 958
|4 555
|
701 |
|
1 |
|3 PPN144973847
|a Lin-Shi
|b Xuefang
|f 1961-...
|4 555
|
701 |
|
1 |
|3 PPN106966316
|a Bethoux
|b Olivier
|f 1967-....
|4 555
|
701 |
|
1 |
|3 PPN243280408
|a Bouarfa
|b Abdelkader
|c ingénieur
|4 555
|
711 |
0 |
2 |
|3 PPN03063525X
|a Centrale Nantes
|c 1991-....
|4 295
|
711 |
0 |
2 |
|3 PPN204770424
|a École doctorale Mathématiques et sciences et technologies de l'information et de la communication
|c Rennes
|4 996
|
711 |
0 |
2 |
|3 PPN203637585
|a Laboratoire des Sciences du Numérique de Nantes
|4 981
|
801 |
|
3 |
|a FR
|b Abes
|c 20230403
|g AFNOR
|
856 |
4 |
|
|q PDF
|s 89010089
|u http://www.theses.fr/2022ECDN0045/document
|z Accès au texte intégral
|
856 |
4 |
|
|u http://www.theses.fr/2022ECDN0045/abes
|
856 |
4 |
|
|u https://tel.archives-ouvertes.fr/tel-04056818
|
930 |
|
|
|5 441092306:784158460
|b 441092306
|j g
|
991 |
|
|
|5 441092306:784158460
|a exemplaire créé automatiquement par STAR
|
998 |
|
|
|a 940824
|